DITYPUMP
search
  • DITYPUMP
  • DITYPUMP
  • DITYPUMP
  • DITYPUMP

DITYPUMP

Reference : 990001

An additional device in the form of a compact, easy-to-carry case offering the option of mobile use. It consists of a compressor for autonomous compressed air access, a DITYBOX and has a capacity of up to four DITYBAGs ! Fully charged, its battery will allow you to recharge your DITYBOX fully up to 27 times.

DITYPUMP

Contact us

The suitcase equipped with a compressor for an autonomous and mobile access to compressed air, rechargeable on sector or cigar lighter. It also comes with a DITYBOX.

Ditypump portable case for Dityspray system

 

SEE THE INSTRUCTIONS FOR USE

SPECIFICATIONS OF THE DITYPUMP

  • Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
  • Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
  • Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».

RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE

In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.

 

DITYBOX AND DITYBAG STORAGE CONDITIONS

shelter from the cold, sunlight and rain.

 

CONDITIONS OF USE

avoid shocks to the DITYBOX.

 

PRESSURIZATION CONDITIONS

  • Pressurize to a maxi-mum of 8 bars.
  • Pressurize with air only.
  • Use only DITYSPRAY consumables.

 

WHAT NOT TO DO

  • Do not use a DITYBOX that appears cracked.
  • Do not use a leaking DITYBOX.
  • Do not attempt to repair a damaged DITYBOX.
  • Do not attempts to open the spray before it is empty.
  • DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.

 

Guaranteed 3 years parts and workforce.

  

DITYPUMP INSTRUCTIONS FOR USE

1 Ditypump unscrew nut 1) Screw out the empty DITYBOX cap.
2 Ditypump introduce ditybag 2) Screw out the DITYBAG cap and fill it into DITYBOX.
3 Ditypump screw nut 3) Screw in cap onto DITYBOX to make airtight the system.
4 Ditypump switch on compressor 4) Switch on the power by pressing On/Reset button and select unit by pressing it again.
5 Ditypump set to 5 bars 5) Adjust pressure level at 5 bars by pressing the Up / Down button. When you stop pushing it, the digital on display will flash 3 times to indicate a pressure level has been set. Then, it will go back to 0. It is ready to inflate.
6 Ditypump air-charging 6) Match the connection of the inflating valve of DITYBOX on the compressor and press it down to supply in air. Press the trigger again to stop or the compressor will automatically stopped when the pressure reached the preset pressure. Always switch off the device properly after the device auto-stopped.
7 Spray your product 7) Spray your product
8 Ditypump depressurize 8) Screw out the cap of DITYBOX.
9 Ditypump unscrew nut 9) Screw out the cap of DITYBOX.
10 Ditypump remove ditybag 10) Take out DITYBAG and close the cap.
11 Ditypump screw in ditybox nut 11) Screw in the cap on DITYBOX.

DITYPUMP user manual

Download (526.96KB)

990001

Data sheet

Product type
Technical product, DITYSPRAY System
Application domain
Maintenance, Complementary products, Substrate preparation, Surface cleaning, Surface maintenance
Packaging
1 per box