DITYPUMP
Reference : 990001
An additional device in the form of a compact, easy-to-carry case offering the option of mobile use. It consists of a compressor for autonomous compressed air access, a DITYBOX and has a capacity of up to four DITYBAGs ! Fully charged, its battery will allow you to recharge your DITYBOX fully up to 27 times.
DITYPUMP
The suitcase equipped with a compressor for an autonomous and mobile access to compressed air, rechargeable on sector or cigar lighter. It also comes with a DITYBOX.
SPECIFICATIONS OF THE DITYPUMP
- Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
- Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
- Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».
RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE
In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.
DITYBOX AND DITYBAG STORAGE CONDITIONS
shelter from the cold, sunlight and rain.
CONDITIONS OF USE
avoid shocks to the DITYBOX.
PRESSURIZATION CONDITIONS
- Pressurize to a maxi-mum of 8 bars.
- Pressurize with air only.
- Use only DITYSPRAY consumables.
WHAT NOT TO DO
- Do not use a DITYBOX that appears cracked.
- Do not use a leaking DITYBOX.
- Do not attempt to repair a damaged DITYBOX.
- Do not attempts to open the spray before it is empty.
- DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.
Guaranteed 3 years parts and workforce.
DITYPUMP INSTRUCTIONS FOR USE
1) Screw out the empty DITYBOX cap. | |
2) Screw out the DITYBAG cap and fill it into DITYBOX. | |
3) Screw in cap onto DITYBOX to make airtight the system. | |
4) Switch on the power by pressing On/Reset button and select unit by pressing it again. | |
5) Adjust pressure level at 5 bars by pressing the Up / Down button. When you stop pushing it, the digital on display will flash 3 times to indicate a pressure level has been set. Then, it will go back to 0. It is ready to inflate. | |
6) Match the connection of the inflating valve of DITYBOX on the compressor and press it down to supply in air. Press the trigger again to stop or the compressor will automatically stopped when the pressure reached the preset pressure. Always switch off the device properly after the device auto-stopped. | |
7) Spray your product | |
8) Screw out the cap of DITYBOX. | |
9) Screw out the cap of DITYBOX. | |
10) Take out DITYBAG and close the cap. | |
11) Screw in the cap on DITYBOX. |
Data sheet
- Product type
- Technical product, DITYSPRAY System
- Application domain
- Maintenance, Complementary products, Substrate preparation, Surface cleaning, Surface maintenance
- Packaging
- 1 per box
You might also like