DITYBOX
Reference : 990000
The DITYBOX is a box / container for the DITYSPRAY system. It is highly secure and totally hermetic once charged with air. It offers a very high resistance to shocks or high pressures and guarantees daily use (reusable up to 5000 times). Its air supply valve located under the housing can be connected to any type of air network.
DITYBOX
Approved transparent TR90 housing that is shock- and wear-resistant, and reusable. DITYBOX is the receptacle for DITYBAGS. DITYBOX has a valve at its base for compressed air supply. The product is propelled by the compressed air pressure on the DITYBAG. A screw-tightening ring is used to seal the system.
SPECIFICATIONS OF THE DITYBOX
- Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
- Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
- Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».
RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE
In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.
DITYBOX AND DITYBAG STORAGE CONDITIONS
shelter from the cold, sunlight and rain.
CONDITIONS OF USE
avoid shocks to the DITYBOX.
PRESSURIZATION CONDITIONS
- Pressurize to a maxi-mum of 8 bars.
- Pressurize with air only.
- Use only DITYSPRAY consumables.
WHAT NOT TO DO
- Do not use a DITYBOX that appears cracked.
- Do not use a leaking DITYBOX.
- Do not attempt to repair a damaged DITYBOX.
- Do not attempts to open the spray before it is empty.
- DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.
Guaranteed 3 years parts and workforce.
DITYBOX INSTRUCTIONS FOR USE
1) Screw out the empty DITYBOX cap. | |
2) Screw out the DITYBAG cap and fill it into DITYBOX. | |
3) Screw in cap onto Ditybox to make airtight the system. | |
4) Match the connection of the inflating valve of DITYBOX to a compressed air network or on the compressor and supply it with air until a pressure of 5 bar is reached. | |
5) Spray your product. | |
6) Empty the remaining air by pressing the DITYBOX’s inflation valve or by connecting it to the deflation tip of your compressor. | |
7) Screw out the cap of DITYBOX. | |
8) Take out DITYBAG and close the cap. | |
9) Screw in the cap on DITYBOX. |
Data sheet
- Volume
- 250 ml
- Product type
- Technical product, DITYSPRAY System
- Application domain
- Maintenance, Complementary products, Substrate preparation, Surface cleaning, Surface maintenance