The DITYBOX is a box / container for the DITYSPRAY system. It is highly secure and totally hermetic once charged with air. It offers a very high resistance to shocks or high pressures and guarantees daily use (reusable up to 5000 times). Its air supply valve located under the housing can be connected to any type of air network.

DITYBOX

Contact us

Approved transparent TR90 housing that is shock- and wear-resistant, and reusable. DITYBOX is the receptacle for DITYBAGS. DITYBOX has a valve at its base for compressed air supply. The product is propelled by the compressed air pressure on the DITYBAG. A screw-tightening ring is used to seal the system.

Ditybox Box

 

SEE THE INSTRUCTIONS FOR USE

 

SPECIFICATIONS OF THE DITYBOX

  • Working pressure and maximum service pressure = 8 bar. Test pressure = 12 bar.
  • Maximum and minimum design temperature TS min / TS max = -5°C / +60°C. Volume V = 0.58L.
  • Pressurisation fluid = air. PED 97/23/EC category = 3.3 - « Conforming to the European directive PED 97/23/EC according to category 3.3 ».

 

RECOMMENDATIONS ON THE MAXIMUM TEMPERATURE AND PRESSURE

In normal use, DITYBOX is designed to operate at a maximum pressure of 8 bar at temperatures between -5°C and +60°C. These pressure and temperature limits must not be exceeded. Overpressure of the DITYBOX (exceeding 8 bar) or exposure to extreme temperatures (below-5°C or above 60°C) may present risks for the user.

 

DITYBOX AND DITYBAG STORAGE CONDITIONS

shelter from the cold, sunlight and rain.

 

CONDITIONS OF USE

avoid shocks to the DITYBOX.

 

PRESSURIZATION CONDITIONS

  • Pressurize to a maxi-mum of 8 bars.
  • Pressurize with air only.
  • Use only DITYSPRAY consumables.

 

WHAT NOT TO DO

  • Do not use a DITYBOX that appears cracked.
  • Do not use a leaking DITYBOX.
  • Do not attempt to repair a damaged DITYBOX.
  • Do not attempts to open the spray before it is empty.
  • DO NOT CHARGE THE DITYBOX WHEN THE COMPRESSOR IS CHARGING.

 

Guaranteed 3 years parts and workforce.

 

 DITYBOX INSTRUCTIONS FOR USE

1 Ditybox unscrew nut 1) Screw out the empty DITYBOX cap.
2 Ditybox introduce ditybag 2) Screw out the DITYBAG cap and fill it into DITYBOX.
3 Ditybox screw nut 3) Screw in cap onto Ditybox to make airtight the system.
4 Ditybox connect valve 4) Match the connection of the inflating valve of DITYBOX to a compressed air network or on the compressor and supply it with air until a pressure of 5 bar is reached.
5 Ditybox product release 5) Spray your product.
6 Ditybox empty air 6) Empty the remaining air by pressing the DITYBOX’s inflation valve or by connecting it to the deflation tip of your compressor.
7 Ditybox unscrew nut 7) Screw out the cap of DITYBOX.
8 Ditybox remove ditybag 8) Take out DITYBAG and close the cap.
9 Ditybox screw back nut 9) Screw in the cap on DITYBOX.